OPTIM EMK: Automatic capacitor banks with static contactor, 50 Hz
Automatic capacitor banks with static contactor, 50 Hz. 19 models, supplied across Saudi Arabia by Volt Solutions.
- Use voltage (V): 440
- 19 models available
Information
The Circutor OPTIM EMK series (automatic capacitor banks with static contactor, 50 Hz) has 19 models. Ordering codes: R46420, R46422, R46424, R46425, R46426, R46431 and 13 more. Model names include OPTIM EMK4-175-440, OPTIM EMK4-250-440, OPTIM EMK4-300-440. Volt Solutions supplies it across Saudi Arabia.
The OPTIM-EMK-series capacitor banks have been designed for power factor correction in networks with fluctuating loads.
The power variations are relatively quick (measured in milliseconds) and the operation is thus carried out by thyristors, which are connected to a voltage controller board, so that the connection and disconnection of the capacitor is carried out with zero voltage difference.
Transients are prevented between the connection and disconnection of the steps, obtaining an immediate response to the load fluctuations.
Applications
The most common application is with individual loads or in installations where a quick compensation response is needed (for ex., welding units, motors for lifting units, lifts, etc.)
Specifications
| Voltage | 400 V (other voltages on request) |
|---|---|
| Reinforcement voltage | 440 V (400 V) |
| Surge | 10 % 8 h over 24 h 15 % up to 15 min over 24 hours 20 % up to 5 min over 24 hours 30 % up to 1 min over 24 hours |
| Discharge resistance | 75 V / 3 min |
| Allowable overload | 1,3 In |
|---|---|
| Permanent overload | 1,3 In |
| Working temperature | Tª class D: Daily average: 45 ºC, annual average: 35 ºC, maximum: 50 ºC, minimum: -25 ºC |
|---|---|
| Relative humidity (without condensation) | 80% |
| Protection class | IP 21 |
| Fastening | Vertical. Minimum distance between condensers 2 cm |
|---|---|
| Thermal management | Natural or forced according to options |
| Components | Three-phase measurement CLZ capacitor Static switching unit at each step, comprising static contactors (thyristors) Individual protection at each step via fuses with high cut-off power (APR), NH-00 or Neosted Series according to type Two-pole circuit breaker protection for battery and regulator operation Max Fast computer series reactive energy regulator Radiators for heat dissipation Thermostat built into the radiator itself to disconnect the step in case of high temperature (90 ºC) |
|---|---|
| Optional | Manual circuit breaker at capacitor bank header Circuit breaker at capacitor bank header Circuit breaker + earth leakage protection at capacitor bank header Forced ventilation unit + thermostat Polycarbonate plate to avoid direct exposure 400/230 V autotransformer |
| Standards | IEC 60831-1, IEC 70/7, UNE-EN 20827, UNE-EN 20010, BS 1650 |
|---|---|
| Certifications | VDE 560 |
| Electrical safety, Maximum height (m) | 2000 |
Models and codes
| Code | Model | Cable section (mm2) | kvar (400 V) | kvar (440 V) | Optional circuit breaker (A) | Optional manual switch (A) | Composition | Quote |
|---|---|---|---|---|---|---|---|---|
| R46420 | OPTIM EMK4-175-440 | 120 | 147 | 175 | 400 | 400 | 25 + 50 + 100 | Get quote |
| R46422 | OPTIM EMK4-250-440 | 185 | 207 | 250 | 630 | 630 | 50 + 2×100 | Get quote |
| R46424 | OPTIM EMK4-300-440 | 240 | 248 | 300 | 630 | 630 | 50 + 50 + 2×100 | Get quote |
| R46425 | OPTIM EMK4-350-440 | 2×150 | 289 | 350 | 630 | 630 | 50 + 3×100 | Get quote |
| R46426 | OPTIM EMK4-400-440 | 2×185 | 331 | 400 | 800 | 800 | 4×100 | Get quote |
| R46431 | OPTIM EMK6-400-440 | 2×185 | 331 | 400 | 800 | 800 | 50 + 50 + 3×100 | Get quote |
| R46435 | OPTIM EMK6-450-440 | 2×185 | 372 | 450 | 800 | 800 | 50 + 4×100 | Get quote |
| R46437 | OPTIM EMK6-550-440 | 2×240 | 455 | 550 | 1000 | 1000 | 50 + 5×100 | Get quote |
| R46438 | OPTIM EMK6-600-440 | 2×240 | 496 | 600 | 1000 | 1000 | 6×100 | Get quote |
| R46442 | OPTIM EMK8-600-440 | 2×240 | 496 | 600 | 1250 | 1250 | 50 + 50 + 5×100 | Get quote |
| R46444 | OPTIM EMK8-650-440 | 3×150 | 537 | 650 | 1250 | 1250 | 50 + 6×100 | Get quote |
| R46450 | OPTIM EMK8-750-440 | 3×185 | 620 | 750 | 1600 | 1600 | 50 + 7×100 | Get quote |
| R46455 | OPTIM EMK8-800-440 | 2×240 / 240 | 661 | 800 | 1600 | 1600 | 8×100 | Get quote |
| R46505 | OPTIM EMK10-850-440 | 2×240 / 240 | 702 | 850 | 1000+630 | 1000+630 | 50 + 8×100 | Get quote |
| R46604 | OPTIM EMK10-950-440 | 2×240 / 2×185 | 785 | 950 | 1000+800 | 1000+800 | 50 + 9×100 | Get quote |
| R46605 | OPTIM EMK10-1000-440 | 2×240 / 2×185 | 826 | 1000 | 1000+800 | 1000+800 | 10×100 | Get quote |
| R46606 | OPTIM EMK12-1050-440 | 2×240 / 2×240 | 868 | 1050 | 1000+800 | 1000+800 | 50 + 10×100 | Get quote |
| R46608 | OPTIM EMK12-1150-440 | 2×240 / 2×240 | 950 | 1150 | 2×1000 | 2×1000 | 50 + 11×100 | Get quote |
| R46609 | OPTIM EMK12-1200-440 | 2×240 / 2×240 | 992 | 1200 | 2×1000 | 2×1000 | 12×100 | Get quote |