ETAP-Power System Studies
Reliable, Accurate, and Safe Power System Analysis
An ETAP study in Saudi Arabia shows whether your electrical network is safe, correctly protected and able to carry its load. Volt Solutions builds a computer model of your installation in ETAP (Electrical Transient Analyzer Program), checks it against site measurements, and gives you ranked findings and settings you can act on.


What you get from an ETAP study
You get a verified computer model of your electrical network and a report that says what is safe, what is not, and what to fix first. It tells you whether your cables and transformers can carry the load, whether your breakers can clear a fault, which device trips first, and how much arc flash energy could reach a person at each panel.
If you want the background first, read our guide on what an ETAP study is. This page covers how we carry one out for plants in Saudi Arabia.
Our ETAP Study Services Include
Load Flow Analysis
Shows voltage, current and losses at every point under normal running, so overloaded feeders and low voltage are found before they cause a failure.
Short Circuit Analysis
Calculates fault current at every bus, typically to IEC 60909, and checks it against the breaking capacity of the equipment installed there.
Arc Flash Studies
Calculates incident energy in cal/cm² using IEEE 1584, then sets the arc flash boundary, PPE category and panel labels in line with NFPA 70E.
Protective Device Coordination
Sets breakers and relays so the device closest to a fault trips first. A fault on one machine should stop that machine, not the whole plant.
Transient Stability & Motor Starting Studies
Tests whether large motors can start without pulling voltage down far enough to drop contactors or stall other equipment.
Harmonic Analysis
Finds where distortion comes from, checks it against IEEE 519, and catches resonance with power factor capacitors before it damages them.
When a Saudi plant needs an ETAP study
Most requests come from one of five situations:
- A new facility or an expansion. Added load changes fault levels and coordination upstream, not only at the new switchboard.
- A compliance or insurance request. Aramco-related work, SEC-connected sites and insurers may ask to see a current study.
- Unexplained trips or repeat failures. If a breaker keeps operating and nobody knows why, the cause is often in the coordination or harmonics.
- An arc flash safety programme. Panel labels and PPE selection need incident energy figures behind them.
- An old study. NFPA 70E calls for the arc flash analysis to be reviewed at least every five years, and whenever a change affects it.
How we carry out the study
- Scope. You send the single-line diagram and tell us what changed recently. We return a scoped quotation within one business day.
- Collect site data. We check transformers, cables and protection settings against what is actually installed, and log real load with Class A power analyzers. We also need the utility fault level from SEC.
- Build and verify the model. Every bus, cable, transformer, motor and protective device goes into ETAP, then the model is checked against the measured values.
- Run the analyses. We run the studies your scope needs and test normal and worst-case operating conditions.
- Report and support. We take you through the findings and can help put the corrections in place, including testing and commissioning afterwards.
For a single-substation facility with reasonable drawings, this typically takes two to four weeks from site data collection to the issued report. Drawings that are out of date add time, because the installation has to be verified on foot.
What you receive
| Deliverable | What you use it for |
|---|---|
| Verified ETAP model | Test future changes in software before making them on site |
| Report with findings ranked by severity | Decide what to fix first, with calculated values you can show an auditor or insurer |
| Protection settings, device by device | Give your technicians settings they can apply directly |
| Arc flash labels for each panel studied | Show incident energy, boundary and PPE at the point of work |
| Prioritised corrective action list | Separate safety problems from lower-priority improvements |
Why conditions in Saudi Arabia matter
Ambient temperatures above 45 °C reduce the real capacity of cables and transformers, so a model built on standard ratings can show headroom the plant does not have. We apply derating for the actual installation conditions. Sites that have expanded over the years also need checking, because fault levels may now exceed what the original switchgear was chosen for.
Recent example: we carried out an ETAP arc flash and short circuit study at a pipe manufacturing plant in the 2nd Industrial City, Riyadh.
Why Choose Volt Solutions?
Experienced ETAP Engineers
Real-world industry experience with proven expertise in power system analysis.
Local Knowledge
Based in Al-Khobar and working across Saudi Arabia, with reports written against SEC, IEC and IEEE requirements.
Reports You Can Act On
Findings come with the calculated values and clear recommendations, not only a pass or fail.
End-to-End Support
From data collection and modelling to the report and help with putting it into practice.
Industries We Serve
Frequently asked questions
How long does an ETAP study take?
Typically two to four weeks from site data collection to the issued report for a single-substation facility with reasonable drawings. Larger networks, or drawings that need verifying on site, take longer.
What do you need from us to start?
The single-line diagram, transformer details, cable schedules, protection device settings and a motor list. We take load measurements ourselves. If some documents are missing, tell us and we will include the survey work in the scope.
Can we order an arc flash study on its own?
An arc flash result depends on fault current and how quickly the upstream device clears. It therefore needs short circuit and coordination data behind it, and we scope those together.
How much does an ETAP study cost?
It depends on the size of the network and how much of it needs verifying on site, mainly the number of buses and protective devices. Send your single-line diagram and we will return a scoped quotation within one business day.
Do you work outside the Eastern Province?
Yes. We are based in Al-Khobar and carry out studies across Saudi Arabia, including the industrial cities in Riyadh and Dammam.
Will the study reduce our electricity bill?
Not directly, because it is mainly a safety and reliability study. Load flow can expose losses and poor power factor, and fixing those can reduce the bill. If cost is your main concern, start with power quality analysis or power factor correction.
Get Your ETAP Study Scoped
Send us your single-line diagram or tell us what the plant is doing. We will tell you which studies you need and return a scoped quotation within one business day.