OPTIM-SVGm: Hybrid var compensators
Manufactured by Circutor

OPTIM-SVGm: Hybrid var compensators

Hybrid var compensators. 14 models, supplied across Saudi Arabia by Volt Solutions.

  • Frequency (Hz): 50 Hz, 60 Hz
  • Use voltage (V): 400, 480
  • 14 models available

Information

The Circutor OPTIM-SVGm series (hybrid var compensators) has 14 models. Ordering codes: RG20F1, RG20F3, RG20F5, RG20F7, RG20F9, RG20FB and 8 more. Model names include OPTIM SVGm-200-440, OPTIM SVGm-300-440, OPTIM SVGm-400-440. Volt Solutions supplies it across Saudi Arabia.

The Hybrid var compensators OPTIM SVGm range consist of a combination of a static reactive power generator, SVGm, and a set of steps of rejection filters tuned to 189 Hz (p = 7%), operated by a contact and controlled by a Computer SMART III power factor regulator.
The use of both technologies in a single compensation unit yields accurate reactive power compensation, with a high capacity to react to power changes that require compensation that represent a percentage of the device’s total power, while providing a high cost to effectiveness ratio, all in a smaller size than the model consisting solely of regulated capacitor steps.
Similarly, the use of a SVGm as a supplement to the contactor-operated steps also provides capacitive power compensation, which is increasingly in demand, and it reduces problems related to the compensation of reactive power in installations containing a self-supply photovoltaic system.

Applications

The Hybrid var compensators OPTIM SVGm range are suitable for reactive power compensation in any installation where the use of rejection filters is required due to the presence of harmonics in the network, but especially in those where, due to the compensation requirements, using a conventional capacitor bank based on steps operated by contactors does not guarantee proper power factor correction that rules out the possibility of being penalized for excess reactive power consumption.
Installations where part of the total power of the compensation device has to respond quickly.
Installations where the addition of a self-supply system based on photovoltaics varies the demand for active power from the network such that a bank with steps does not cover the compensation needs, or those where at certain times, there is excess capacitive power, which is also subject to penalization.

Specifications

AC power supply
Installation category4 kV, CAT III Class 1
Electrical characteristics
Conditional short-circuit current (Icc)40 kA
Earthing systemTN, TT
Current measurement circuit
Consumption1,5 VA x transf.
Transformation ratio5/5A … 9000/5A
Environmental characteristics
Relative humidity (without condensation)0 … 95 %
Protection classIP20
Mechanical characteristics
Noise< 63 dBA
Protection
ElementIndividual protection of each step with fuses with high rupture power (HRP). NH-00 Series.
Standards
StandardsIEC 61439-2
Electrical safety, Contamination level/classCategory 2
Electrical safety, Maximum height (m)2000 m

Models and codes

CodeModel Frequency (Hz)Stepskvar (400 V)kvar (440 V)CompositionUse voltage (V) Quote
RG20F1 OPTIM SVGm-200-440 50 Hz21822001 x 100 kvar + 100 kvar400 Get quote
RG20F3 OPTIM SVGm-300-440 50 Hz32643002 x 100 kvar + 100 kvar400 Get quote
RG20F5 OPTIM SVGm-400-440 50 Hz43464003 x 100 kvar + 100 kvar400 Get quote
RG20F7 OPTIM SVGm-500-440 50 Hz54285004 x 100 kvar + 100 kvar400 Get quote
RG20F9 OPTIM SVGm-600-440 50 Hz65106005 x 100 kvar + 100 kvar400 Get quote
RG20FB OPTIM SVGm-700-440 50 Hz75927006 x 100 kvar + 100 kvar400 Get quote
RG20FD OPTIM SVGm-800-440 50 Hz86748007 x 100 kvar + 100 kvar400 Get quote
RG26F1 OPTIM SVGm-175-480-60Hz 60 Hz2––1 x 75 kvar + 100 kvar480 Get quote
RG26F3 OPTIM SVGm-250-480-60Hz 60 Hz3––2 x 75 kvar + 100 kvar480 Get quote
RG26F5 OPTIM SVGm-325-480-60Hz 60 Hz4––3 x 75 kvar + 100 kvar480 Get quote
RG26F7 OPTIM SVGm-400-480-60Hz 60 Hz5––4 x 75 kvar + 100 kvar480 Get quote
RG26F9 OPTIM SVGm-475-480-60Hz 60 Hz6––5 x 75 kvar + 100 kvar480 Get quote
RG26FB OPTIM SVGm-550-480-60Hz 60 Hz7––6 x 75 kvar + 100 kvar480 Get quote
RG26FD OPTIM SVGm-625-480-60Hz 60 Hz8––7 x 75 kvar + 100 kvar480 Get quote

Downloads