Manufactured by Circutor
LCL: Harmonic filters for power converters
Harmonic filters for power converters. 9 models, supplied across Saudi Arabia by Volt Solutions.
- Frequency (Hz): 50, 60
- cabinet: LCL TH, FRF, FR4, FR6
- 9 models available
Information
The Circutor LCL series (harmonic filters for power converters) has 9 models. Ordering codes: R73107, R732140070000, R732150070000, R732160070000, R732170070000, R732180070000 and 3 more. Model names include LC L35-16A-400, LC L36-76A-480, LC L36-90A-480. Volt Solutions supplies it across Saudi Arabia.
LCL filters have been specially designed to eliminate the harmonics from the current absorbed by 6-pulse power converters, such as frequency variators for motors, UPS, etc. These are essentially passive filters based on a series-parallel combination of inductances and capacitors, adapted to filter the input of power converters.
Applications
- Reduction of the current wave’s distortion towards the network and the rest of the installation.
- Compliance with the IEC 61000-3-4, IEC 61000-3-12, IEC 61800-3 and IEEE-519.
- Energy savings with the reduction of the root mean square current (RMS), thus reducing the kV·A demand.
- Increase of the working life of units above this location with the corresponding reduction of thermal losses generated.
- Limits current transients, preventing damages caused to the converter and overvoltage trips that affect production processes.
Specifications
| Nominal voltage | 400 Vca /480 Vca F-F (otras tensiones, bajo demanda) |
|---|
| Residual current THD | Approx. 8% |
|---|---|
| Nominal current voltage drop | < 2 % |
| Allowable overload | 1,5 Ic (≤ 1 min.) + Ic (≤ 5 min.) (at maximum operating temperature) |
|---|
| Operating temperature | + 35 ºC |
|---|---|
| Relative humidity (without condensation) | 80% |
| Protection class | IP 20 |
| Installation, location, position. | Inside |
| Envelope | Treated and painted steel. Frame RAL 1013 / Doors RAL 3005 |
|---|---|
| Fastening | On the ground |
| Standards | UNE-EN 60439 , UNE-EN60831 , IEC 61000-6-3 , IEC 61000-6-4, Class A |
|---|
Models and codes
| Code | Model | Load current (A) | Frequency (Hz) | Q (kvar) | cabinet | Quote |
|---|---|---|---|---|---|---|
| R73107 | LC L35-16A-400 | 16 | 50 | 3,27 | LCL TH | Get quote |
| R732140070000 | LC L36-76A-480 | 76 | 60 | 22,77 | FRF | Get quote |
| R732150070000 | LC L36-90A-480 | 90 | 60 | 26,56 | FR4 | Get quote |
| R732160070000 | LC L36-110A-480 | 110 | 60 | 30,36 | FR4 | Get quote |
| R732170070000 | LC L36-150A-480 | 150 | 60 | 45,53 | FR4 | Get quote |
| R732180070000 | LC L36-180A-480 | 180 | 60 | 53,12 | FR4 | Get quote |
| R732190070000 | LC L36-220A-480 | 220 | 60 | 60,71 | FR4 | Get quote |
| R732200070000 | LC L36-260A-480 | 260 | 60 | 68,3 | FR4 | Get quote |
| R732210070000 | LC L36-320A-480 | 320 | 60 | 91,07 | FR6 | Get quote |