TRM: Measuring transformers encapsulated in resin
Measuring transformers encapsulated in resin. 50 models, supplied across Saudi Arabia by Volt Solutions.
- System: Single-phase
- Transformer type: Encapsulated in resin
- Class 1 Power (VA): 2, 5
- 50 models available
Information
The Circutor TRM series (measuring transformers encapsulated in resin) has 50 models. Ordering codes: P50101, P50102, P50103, P50104, P50105, P50106 and 44 more. Model names include TRM30 75/5A, TRM30 100/5A, TRM30 150/5A. Volt Solutions supplies it across Saudi Arabia.
Resin-coated current transformer, busbar. Other characteristics:
- From 75 to 5000 A
- Inner diameter from 30 to 180 mm, according to type
- Secondary …/5 A ( …/1 A on request)
Applications
These transformers have been conceived to convert nominal currents in any installation to current values adjusted to measurement devices. Its synthetic resin increases its resistance to adverse environmental conditions.
Specifications
| Insulation voltage between terminals S1-S2 | 3 kV |
|---|
| Transformation ratio | … / 5 A |
|---|---|
| Nominal frequency | 50 / 60 Hz |
| Dynamic current (Idyn) | 2,5 Ith |
| Thermal short-circuit current (Ith) | 60 In |
| Operating voltage | 0,72 kV~ max. |
|---|
| Thermal Class | Class B (+130 ºC) |
|---|
| Envelope | Self-extinguishing V0, synthetic resin |
|---|
| Standards | IEC 60044-1 / UNE EN 60044-1 |
|---|
Models and codes
| Code | Model | Inner diameter (mm) | Class 1 Power (VA) | Measurement Range (A) | Input current | Class 0,5 Power (VA) | Quote |
|---|---|---|---|---|---|---|---|
| P50101 | TRM30 75/5A | 30 | 2 | 75/5 | 75 A | – | Get quote |
| P50102 | TRM30 100/5A | 30 | 5 | 100/5 | 100 A | – | Get quote |
| P50103 | TRM30 150/5A | 30 | 5 | 150/5 | 150 A | – | Get quote |
| P50104 | TRM30 200/5A | 30 | – | 200/5 | 200 A | 10 | Get quote |
| P50105 | TRM30 250/5A | 30 | – | 250/5 | 250 A | 15 | Get quote |
| P50106 | TRM30 300/5A | 30 | – | 300/5 | 300 A | 20 | Get quote |
| P50107 | TRM30 400/5A | 30 | – | 400/5 | 400 A | 25 | Get quote |
| P50111 | TRM40 150/5A | 40 | – | 150/5 | 150 A | 5 | Get quote |
| P50112 | TRM40 200/5A | 40 | – | 200/5 | 200 A | 7,5 | Get quote |
| P50113 | TRM40 250/5A | 40 | – | 250/5 | 250 A | 10 | Get quote |
| P50114 | TRM40 300/5A | 40 | – | 300/5 | 300 A | 15 | Get quote |
| P50115 | TRM40 400/5A | 40 | – | 400/5 | 400 A | 20 | Get quote |
| P50116 | TRM40 500/5A | 40 | – | 500/5 | 500 A | 25 | Get quote |
| P50117 | TRM40 600/5A | 40 | – | 600/5 | 600 A | 30 | Get quote |
| P50118 | TRM40 800/5A | 40 | – | 800/5 | 800 A | 35 | Get quote |
| P50121 | TRM60 250/5A | 60 | – | 250/5 | 250 A | 5 | Get quote |
| P50122 | TRM60 300/5A | 60 | – | 300/5 | 300 A | 7,5 | Get quote |
| P50123 | TRM60 400/5A | 60 | – | 400/5 | 400 A | 10 | Get quote |
| P50124 | TRM60 500/5A | 60 | – | 500/5 | 500 A | 15 | Get quote |
| P50125 | TRM60 600/5A | 60 | – | 600/5 | 600 A | 20 | Get quote |
| P50126 | TRM60 800/5A | 60 | – | 800/5 | 800 A | 25 | Get quote |
| P50127 | TRM60 1000/5A | 60 | – | 1000/5 | 1000 A | 30 | Get quote |
| P50128 | TRM60 1200/5A | 60 | – | 1200/5 | 1200 A | 35 | Get quote |
| P50131 | TRM80 500/5A | 80 | – | 500/5 | 500 A | 5 | Get quote |
| P50132 | TRM80 600/5A | 80 | – | 600/5 | 600 A | 7,5 | Get quote |
| P50133 | TRM80 750/5A | 80 | – | 750/5 | 750 A | 10 | Get quote |
| P50134 | TRM80 1000/5A | 80 | – | 1000/5 | 1000 A | 15 | Get quote |
| P50135 | TRM80 1500/5A | 80 | – | 1500/5 | 1500 A | 20 | Get quote |
| P50136 | TRM80 2000/5A | 80 | – | 2000/5 | 2000 A | 25 | Get quote |
| P50137 | TRM80 2500/5A | 80 | – | 2500/5 | 2500 A | 30 | Get quote |
| P50141 | TRM100 750/5A | 100 | – | 750/5 | 750 A | 15 | Get quote |
| P50142 | TRM100 1000/5A | 100 | – | 1000/5 | 1000 A | 20 | Get quote |
| P50144 | TRM100 1500/5A | 100 | – | 1500/5 | 1500 A | 20 | Get quote |
| P50145 | TRM100 2000/5A | 100 | – | 2000/5 | 2000 A | 20 | Get quote |
| P50146 | TRM100 2500/5A | 100 | – | 2500/5 | 2500 A | 20 | Get quote |
| P50147 | TRM100 3000/5A | 100 | – | 3000/5 | 3000 A | 25 | Get quote |
| P50151 | TRM140 1000/5A | 140 | – | 1000/5 | 1000 A | 15 | Get quote |
| P50152 | TRM140 1250/5A | 140 | – | 1250/5 | 1250 A | 20 | Get quote |
| P50153 | TRM140 1500/5A | 140 | – | 1500/5 | 1500 A | 25 | Get quote |
| P50154 | TRM140 2000/5A | 140 | – | 2000/5 | 2000 A | 30 | Get quote |
| P50155 | TRM140 2500/5A | 140 | – | 2500/5 | 2500 A | 35 | Get quote |
| P50156 | TRM140 3000/5A | 140 | – | 3000/5 | 3000 A | 35 | Get quote |
| P50157 | TRM140 4000/5A | 140 | – | 4000/5 | 4000 A | 35 | Get quote |
| P50161 | TRM180 1250/5A | 180 | – | 1250/5 | 1250 A | 15 | Get quote |
| P50162 | TRM180 1500/5A | 180 | – | 1500/5 | 1500 A | 20 | Get quote |
| P50163 | TRM180 2000/5A | 180 | – | 2000/5 | 2000 A | 20 | Get quote |
| P50164 | TRM180 2500/5A | 180 | – | 2500/5 | 2500 A | 20 | Get quote |
| P50165 | TRM180 3000/5A | 180 | – | 3000/5 | 3000 A | 20 | Get quote |
| P50166 | TRM180 4000/5A | 180 | – | 4000/5 | 4000 A | 20 | Get quote |
| P50167 | TRM180 5000/5A | 180 | – | 5000/5 | 5000 A | 20 | Get quote |
Downloads