AC Current Transformers

AC current transformers reduce the current in a cable or busbar to a value that a meter or analyzer can read. Use split-core types to add metering without disconnecting cables, and solid-core types for new panels.

Request a quote
AC Current Transformers

12 product series

TD: Current transformers narrow section Circutor

TD: Current transformers narrow section

Current transformers narrow section. 75 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Closed core75 models available View product, 75 models
TDH: High precision current transformer Circutor

TDH: High precision current transformer

High precision current transformer. 72 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Closed core72 models available View product, 72 models
TP: Current transformers, split core Circutor

TP: Current transformers, split core

Current transformers, split core. 38 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Split coreFlat strip(mm): 30×30, 60X80, 80×120, 80×160Inner diameter (mm): 30, 60, 80 View product, 38 models
TQR: Current transformers split core Circutor

TQR: Current transformers split core

Current transformers split core. 18 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Split coreInner diameter (mm): 80, 10518 models available View product, 18 models
SCV1: Kit 3 Split core current transformers Circutor

SCV1: Kit 3 Split core current transformers

Kit 3 Split core current transformers. 1 model, supplied across Saudi Arabia by Volt Solutions. Inner diameter (mm): 15System: Three-phaseClass 0,5 Power (VA): o,5Max. Current (A): 100 View product, 1 model
STQ: Current transformers, split core Circutor

STQ: Current transformers, split core

Current transformers, split core. 16 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Split coreClass 3 Power (VA): 1, 0,1Input current: 100 A, 150 A, 200 A, 250 A, 300 A, 50 A View product, 16 models
SC3: Split three-phase current transformers Circutor

SC3: Split three-phase current transformers

Split three-phase current transformers. 1 model, supplied across Saudi Arabia by Volt Solutions. Inner diameter (mm): 15System: Three-phaseClass 0,5 Power (VA): 0,1Max. Current (A): 125 View product, 1 model
MC1-MC3: Current transformers Circutor

MC1-MC3: Current transformers

Current transformers. 10 models, supplied across Saudi Arabia by Volt Solutions. Transformer type: Closed coreSystem: Three-phase, Single-phaseClass 0,5 Power (VA): 0,1, 0,2510 models available View product, 10 models
TM45: Current transformers, winding primary, DIN rail Circutor

TM45: Current transformers, winding primary, DIN rail

Current transformers, winding primary, DIN rail. 9 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseClass 0,5 Power (VA): 2,5Class 1 Power (VA): 5Class 3 Power (VA): 7 View product, 9 models
TA210: Current transformers, winding primary Circutor

TA210: Current transformers, winding primary

Current transformers, winding primary. 18 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseClass 1 Power (VA): 20Class 3 Power (VA): 30Transformer type: Winding primary View product, 18 models
TA: Current transformers Circutor

TA: Current transformers

Current transformers. 28 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Closed coreFlat strip(mm): 100 x 20, 100 x 30, 125 x 60Class 0,5 Power (VA): 5, 15, 20, 35, 30, 40 View product, 28 models
TRM: Measuring transformers encapsulated in resin Circutor

TRM: Measuring transformers encapsulated in resin

Measuring transformers encapsulated in resin. 50 models, supplied across Saudi Arabia by Volt Solutions. System: Single-phaseTransformer type: Encapsulated in resinClass 1 Power (VA): 2, 550 models available View product, 50 models

Accessories and other codes

CodeModel Flat strip(mm)Class 0,2 Power (VA)Class 0,2S Power (VA)Class 0,5S Power (VA)Measurement Range (A)Input current Quote
M70444 TCH6.2 200/5A 20 x 20 |25 x 12 |30 x 1053,55200/5200 A Get quote
M70476 TCH10 1600/5A 50 x 50 |60 x 30 |80 x 301010151600/51600 A Get quote

How to choose a current transformer

  • Existing installation, no shutdown: split-core TP, TQR, STQ, SCV1 or SC3
  • New panel: narrow-section TD, or TDH where accuracy matters
  • Low currents: wound-primary TM45, TA210 or TA
  • Three phases in one body: MC1-MC3 or SC3

Four details decide the code: primary current, secondary (5 A, 1 A or mV/mA for the analyzer), accuracy class with burden in VA, and the window size for your cable or busbar. Send us those four and we will confirm the model.

Frequently asked questions

Can a CT be fitted without switching off?

Split-core transformers open around the conductor, so nothing has to be disconnected. Safe working still applies: fitting near live parts must be done by qualified people under a suitable procedure.

What accuracy class do I need?

Class 0.5 or better is usual for energy metering, and class 1 or 3 for indication. The burden of the meter and cable must stay within the VA rating at that class.

Know the part number? Measurement and Control Product Codes

Talk to a specialist

Request a quotation or datasheet

Tell us the model or the application. An engineer replies within one business day.

Call an engineer WhatsApp us