Computer PV12: Reactive energy regulator for photovoltaic applications
Manufactured by Circutor

Computer PV12: Reactive energy regulator for photovoltaic applications

Reactive energy regulator for photovoltaic applications. 1 model, supplied across Saudi Arabia by Volt Solutions.

  • Alarm relay: Yes
  • Communications: RS-485
  • Measurement Range (V): 20…300
  • IΔn (A): yes
  • Power supply: 100…520 Vac
  • Steps: 12
  • Input current: … /5 A, … /1 A.
  • Switching unit: Contactor

Information

The Circutor Computer PV12 series (reactive energy regulator for photovoltaic applications) has 1 model. Ordering code: R13882. Volt Solutions supplies it across Saudi Arabia.

The Computer PV12 is a power factor controller designed for installations with photovoltaic self-consumption and for applications where it is necessary to sum currents from different energy sources.
The device measures the cos φ of the network and controls capacitor connection and disconnection to maintain it at the target value. Additionally, it calculates and displays the main electrical parameters in single-phase and balanced three-phase networks.

The measurement is carried out in true effective value (True RMS) through 4 AC voltage inputs, 3 independent current inputs, and 1 input for measuring leakage current.
The Computer PV12 range allows up to 3 independent energy source measurements and combines them into a total reading.

Applications

The connection with 1, 2, or 3 current transformers allows the Computer PV12 to sum the contributions of different energy sources, making it ideal for photovoltaic self-consumption installations where a conventional controller may struggle to correctly read and compensate the cos φ.

It is also suitable for installations requiring up to 4 cos φ targets, enabling the compensation to adapt to different needs, for instance across time slots.

Specifications

AC power supply
Nominal voltage100 … 520 V ~
Frequency50 … 60 Hz
Consumption13 … 20 VA
Installation categoryCAT III 300 V
Voltage measurement circuit
Nominal voltage230 V Ph-N, 400 V Ph-Ph
Voltage measuring range20…300 V Ph-N , 35…520 V Ph-Ph
Frequency measuring range45 … 65 Hz
Input impedance660 kΩ
Minimum measurement voltage (Vstart)20 V F-N, 35 V F-F
Installation categoryCAT III 300 V
Sampling frequency45 … 65 Hz
Current measurement circuit
Nominal current (In)…/5A ó …/1A
Phase current measuring range1 … 120 % In
Minimum current measurement50 mA
Measurement accuracy
Phase voltage measurement0.5% ± 1 digit
Phase current measurement0.5% ± 1 digit
Active power measurement (kW)0.5% ± 2 digits
Reactive power measurement (kvar)1% ± 2 digit
Active energy measurement (kWh)Class 1
Reactive energy measurement (kvarh)Class 1
Leakage current measurement (ID)
Minimum current measurement (Istart)10 mA
Measurement range0,01 … 1,5 A
Digital transistor outputs
TypeNPN
Maximum current50 mA
Digital relay outputs
Quantity14 (12 salidas, 1 ventilador, 1 alarma)
Maximum open contact voltage1 kV
Maximum current1A
Electrical life30 x 10 3 ciclos
Mechanical life5 x 10 6 Cycles
Maximum switching capacity2500 VA
Digital inputs
TypePotential-free contact
Input/output insulationOptoisolated
Serial communication
Technology / TypeRS-485
ProtocolModbus RTU
User interface
Display typeLCD Custom COG
LED4 LED
KeyboardCapacitive, 5 keys
Environmental characteristics
Working temperature-10 … +55 ºC
Storage temperature-20 … +70 ºC
Relative humidity (without condensation)5 … 95%
Protection classIP 51 (Front), IP 31 (unmounted)
Mechanical characteristics
EnvelopePlastic V0 self-extinguishing
FasteningPanel
Weight (kg)0,6
Size (mm) width x height x depth144 x 144 x 71 (mm)
Standards
StandardsIEC 61010, IEC 61000-6-2, IEC 61000-6-4, Medidas conforme a : IEC 61557-12
Electrical safety, Maximum height (m)2000

Models and codes

CodeModel Alarm relayCommunicationsMeasurement Range (V)IΔn (A) Quote
R13882 Computer PV 12 YesRS-48520…300yes Get quote

Downloads

Support from our engineers

You may also be interested in