DIR: Power factor relay 1 step. DIN rail
Power factor relay 1 step. DIN rail. 1 model, supplied across Saudi Arabia by Volt Solutions.
- Alarm relay: No
- Power supply (Vac): 400 Vac
- Steps: 1
- Input current: …/250 mA
- Switching unit: Contactor
Information
The Circutor DIR series (power factor relay 1 step. DIN rail) has 1 model. Ordering code: R11211. Volt Solutions supplies it across Saudi Arabia.
The DIR2 Power Factor Relay is capable of acting on a circuit in accordance with the reactive inductive or capacitive current transmitted through it. The DIR2 relay measures reactive current in mA of the secondary of a …/250 mA current transformer MC1 or MC3 type. The front of the relay has a control panel that is used to adjust the reactive current where the relay will act. It has a LED that indicates the status of the relay.
Applications
The DIR2 relay is easy to install and program, making it the best solution in the following applications:
- Individual compensation of small, medium or large power loads.
- Partial compensation in installations with automatic equipment available.
- Partial or total regulator in low-power installations.Instantaneous and total disconnection of capacitor banks when there is a high capacitive current in the network.
- Control of reactive currents- capacitive and inductive – triggering an alarm signal when a high current is detected.
Specifications
| Nominal voltage | 400 V ~ ±10% |
|---|---|
| Frequency | 50-60 Hz |
| Consumption | < 3 VA |
| Nominal current (In) | 0,25 A ~ |
|---|---|
| Allowable overload | 1,2 In |
| Consumption | < 0,05 VA |
| Permanent overload | 1,2 In |
| C/K trip adjustment range | 0,15 … 2 |
|---|---|
| Connection delay Tc | 5 s |
| Disconnection delay Tr | 2 s |
| Thermal current (Ith) | 10 A |
|---|---|
| DC11 Ie/Ue | 0,3 A / 110 V dc |
| AC11 Ie/Ue | 10 A / 250 V ~ |
| Electrical life | 10×10 4 maniobras |
| Mechanical life | 10×10 6 operations |
| Working temperature | -10 … +50 ºC |
|---|---|
| Relative humidity (without condensation) | 95% |
| Protection class | IP 40 |
| Standards | EN 61010, EN 61000-3-2, EN 61000-3-3, EN 50081-2, EN 50082-1, EN 50082-2, EN 61000-4-2, EN 61000-4-4, EN 61000-4-8, EN 61000-4-5, EN 61000-4-11, UL 94 |
|---|---|
| Certifications | UL |
| Electrical safety, Maximum height (m) | 2000 |
| Insulation | Double-insulated electric shock protection class II (IEC 61010-1) |
|---|
| Weight (kg) | 0,1 |
|---|---|
| Size (mm) width x height x depth | 35 x 85 x 73 (mm) |
Models and codes
| Code | Model | Alarm relay | Power supply (Vac) | Steps | Input current | Quote |
|---|---|---|---|---|---|---|
| R11211 | DIR2 | No | 400 Vac | 1 | …/250 mA | Get quote |