OPTIM FR P&P 60Hz: LV fixed or contactor switched automatic capacitor banks
Manufactured by Circutor

OPTIM FR P&P 60Hz: LV fixed or contactor switched automatic capacitor banks

Automatic capacitor banks with detuned filters (contactors switching), type P=7% (fres=227 Hz), 60 Hz. 43 models, supplied across Saudi Arabia by Volt Solutions.

  • Mounting: Floor-mounted
  • P%: 7
  • Use voltage (V): 240, 480
  • 43 models available

Information

The Circutor OPTIM FR P&P 60Hz series (LV fixed or contactor switched automatic capacitor banks) has 43 models. Ordering codes: R54RBN, R54RBP, R54RBS, R54SF0, R54SF2, R54SF3 and 37 more. Model names include OPTIM FRS P&P-25-240-60Hz, OPTIM FRS P&P-30-240-60Hz, OPTIM FRS P&P-40-240-60Hz. Volt Solutions supplies it across Saudi Arabia.

The OPTIM FR P&P Series capacitor banks with detuned filters have been designed for power compensation purposes in networks with fluctuating load levels, a high content of harmonics and where there is a risk of resonance. Power variations are relatively slow (in seconds) so that the switching operations are carried out with contactors.

Applications

Its application is mainly focused on the compensation of installations with different loads, which require a regulated compensation, as a result of the power factor variations and where there is a high content of harmonics in the network.

  • Fixed detuned filters. For the compensation of transformers and motors (OPTIM FRF / FRM)
  • Automatic detuned filters, For the monitoring of variable loads (OPTIM FR P&P).

Specifications

AC power supply
Frequency60 Hz
Electrical characteristics
Surge10 % 8 h over 24 h 15 % up to 15 min over 24 hours 20 % up to 5 min over 24 hours 30 % up to 1 min over 24 hours
Manoeuvre voltageContactors: 230 V
Discharge resistance75 V / 3 min
Tolerance C-5% / 10 %
Losses (W)< 0,5 W/kvar
Current measurement circuit
Permanent overload1,3 In
Transformation ratioIn / 5A
Environmental characteristics
Working temperatureTª class D: Daily average: 45 ºC, annual average: 35 ºC, maximum: 55 ºC, minimum: -50 ºC
Relative humidity (without condensation)80%
Protection classIP 21
Mechanical characteristics
EnvelopeSheet metal RAL 7035 Grey / RAL 3005 Garnet
FasteningVertical / Self-supporting
Thermal managementNatural or forced according to options
Protection
ElementIndividual protection of each step with fuses with high rupture power (HRP). NH-00 Series.

Models and codes

CodeModel kvar (240 V)Aut.Switch (A)CompositionUse voltage (V)kvar (480 V) Quote
R54RBN OPTIM FRS P&P-25-240-60Hz 253 x 1002×5+10240– Get quote
R54RBP OPTIM FRS P&P-30-240-60Hz 303 x 1253×10240– Get quote
R54RBS OPTIM FRS P&P-40-240-60Hz 403 x 1604×10240– Get quote
R54SF0 OPTIM FR4 P&P-37,5-240-60Hz 37,53 x 1253×12,5240– Get quote
R54SF2 OPTIM FR4 P&P-50-240-60Hz 503 x 2002×12,5+25240– Get quote
R54SF3 OPTIM FR4 P&P-62,5-240-60Hz 62,53 x 25012,5+2×25240– Get quote
R54SF4 OPTIM FR4 P&P-75-240-60Hz 753 x 2503×25240– Get quote
R54SF5 OPTIM FR4 P&P-87,5-240-60Hz 87,53 x 40012,5+3×25240– Get quote
R54SF6 OPTIM FR4 P&P-100-240-60Hz 1003 x 4004×25240– Get quote
R54SF8 OPTIM FR4 P&P-140-240-60Hz 1403 x 40020+3×40240– Get quote
R54SF9 OPTIM FR4 P&P-160-240-60Hz 1603 x 6304×40240– Get quote
R54SG3 OPTIM FR6 P&P-180-240-60Hz 1803 x 63020+4×40240– Get quote
R54SG4 OPTIM FR6 P&P-200-240-60Hz 2003 x 6305×40240– Get quote
R54SG6 OPTIM FR6 P&P-220-240-60Hz 2203 x 80020+5×40240– Get quote
R54SG7 OPTIM FR6 P&P-240-240-60Hz 2403 x 8006×40240– Get quote
R54SH1 OPTIM FR8 P&P-280-240-60Hz 2803 x 10007×40240– Get quote
R54SH2 OPTIM FR8 P&P-320-240-60Hz 3203 x 10008×40240– Get quote
R54SJ4 OPTIM FR10 P&P-360-240-60Hz 3603 x 12509×40240– Get quote
R54SJ6 OPTIM FR10 P&P-400-240-60Hz 4003 x 125010×40240– Get quote
R54SK4 OPTIM FR12 P&P-440-240-60Hz 4403 x 160011×40240– Get quote
R54SK6 OPTIM FR12 P&P-480-240-60Hz 4803 x 160012×40240– Get quote
R54RB2 OPTIM FRS P&P-50-480-60Hz –3 x 1002×12,5+2548050 Get quote
R54RB4 OPTIM FRS P&P-75-480-60Hz –3 x 1253×2548075 Get quote
R54RB9 OPTIM FRS P&P-100-480-60Hz –3 x 1604×25480100 Get quote
R54SB4 OPTIM FR4 P&P-75-480-60Hz –3 x 1253×2548075 Get quote
R54SB6 OPTIM FR4 P&P-100-480-60Hz –3 x 2002×25+50480100 Get quote
R54SB7 OPTIM FR4 P&P-125-480-60Hz –3 x 25025+2×50480125 Get quote
R54SB3 OPTIM FR4 P&P-150-480-60Hz –3 x 2502×25+2×50480150 Get quote
R54SB0 OPTIM FR4 P&P-175-480-60Hz –3 x 40025+3×50480175 Get quote
R54SB9 OPTIM FR4 P&P-200-480-60Hz –3 x 4004×50480200 Get quote
R54SB8 OPTIM FR4 P&P-262,5-480-60Hz –3 x 40037,5+3×75480262,5 Get quote
R54SB5 OPTIM FR4 P&P-300-480-60Hz –3 x 6304×75480300 Get quote
R54TB3 OPTIM FR6 P&P-337,5-480-60Hz –3 x 63037,5+4×75480337,5 Get quote
R54TB4 OPTIM FR6 P&P-375-480-60Hz –3 x 6305×75480375 Get quote
R54TB6 OPTIM FR6 P&P-412,5-480-60Hz –3 x 80037,5+5×75480412,5 Get quote
R54TB7 OPTIM FR6 P&P-450-480-60Hz –3 x 8006×75480450 Get quote
R54UC0 OPTIM FR8 P&P-487,5-480-60Hz –3 x 80037,5+6×75480487,5 Get quote
R54UC1 OPTIM FR8 P&P-525-480-60Hz –3 x 10007×75480525 Get quote
R54UC2 OPTIM FR8 P&P-600-480-60Hz –3 x 10008×75480600 Get quote
R54VB4 OPTIM FR10 P&P-675-480-60Hz –3 x 12509×75480675 Get quote
R54VB6 OPTIM FR10 P&P-750-480-60Hz –3 x 125010×75480750 Get quote
R54WD1 OPTIM FR12 P&P-825-480-60Hz –3 x 160011×75480825 Get quote
R54WD2 OPTIM FR12 P&P-900-480-60Hz –3 x 160012×75480900 Get quote

Downloads