OPTIM FRM: Fixed capacitors with detuned reactor of P = 7% (fres=189 Hz), 50 Hz
Fixed capacitors with detuned reactor of P = 7% (fres=189 Hz), 50 Hz. 6 models, supplied across Saudi Arabia by Volt Solutions.
- Cut off power: 50 kA
- Use voltage (V): 440
- Cable section (mm2): 10, 16, 25, 35, 50, 70
- kvar (400 V): 21, 31, 42, 50, 62, 83
- kvar (440 V): 25, 37,5, 50, 60, 75, 100
- 6 models available
Information
The Circutor OPTIM FRM series (fixed capacitors with detuned reactor of P = 7% (fres=189 Hz), 50 Hz) has 6 models. Ordering codes: R5Y350, R5Y370, R5Y380, R5Y390, R5Y3A0, R5Y3B0. Model names include OPTIM FRM-25-440, OPTIM FRM-37,5-440, OPTIM FRM-50-440. Volt Solutions supplies it across Saudi Arabia.
The FRF / FRM Series capacitor banks with detuned filters have been designed for power compensation purposes in motors and transformers with a constant load level, a high content of harmonics and where there is a risk of resonance. Including:
- FRF: general protection with NH-00 fuses with a high rupture power (HRP) for the capacitor.
- FRM: general circuit breaker protection for the capacitor.
Applications
Its application is mainly based on the compensation of transformers and motors. In general, it is used for the compensation of installations under constant loads and where there is a high content of harmonics in the network.
Specifications
| Reinforcement voltage | 440 V |
|---|---|
| Discharge resistance | 75 V / 3 min |
| Tolerance C | ±10 % |
| Losses (W) | Dielectric: < 0.2 W/kvar Total: < 0.5 W/kvar |
| Permanent overload | 1,3 In |
|---|
| Relative humidity (without condensation) | 80% |
|---|---|
| Protection class | IP 21 |
| Fastening | Vertical |
|---|---|
| Thermal management | Natural or forced according to options |
| Size (mm) width x height x depth | 650 x 1060 x 420 (mm) |
| Element | Individual protection of each step with fuses with high rupture power (HRP). NH-00 Series. |
|---|
| Components | CF Capacitor General tripolar circuit breaker for protection. Waste filters tuned to 189 Hz to protect harmonics present in the network and avoid resonance phenomena with harmonics of order 5 or more. It incorporates a thermostat to disconnect the step in case of high temperature (90 ºC). |
|---|
| Electrical safety, Maximum height (m) | 2000 m |
|---|
Models and codes
| Code | Model | Cable section (mm2) | kvar (400 V) | kvar (440 V) | Quote |
|---|---|---|---|---|---|
| R5Y350 | OPTIM FRM-25-440 | 10 | 21 | 25 | Get quote |
| R5Y370 | OPTIM FRM-37,5-440 | 16 | 31 | 37,5 | Get quote |
| R5Y380 | OPTIM FRM-50-440 | 25 | 42 | 50 | Get quote |
| R5Y390 | OPTIM FRM-60-440 | 35 | 50 | 60 | Get quote |
| R5Y3A0 | OPTIM FRM-75-440 | 50 | 62 | 75 | Get quote |
| R5Y3B0 | OPTIM FRM-100-440 | 70 | 83 | 100 | Get quote |
Downloads
We send the manufacturer datasheet, manual and drawings for the exact model you need. Request the datasheet