OPTIM FR P&P: LV fixed or contactor switched automatic capacitor banks
Manufactured by Circutor

OPTIM FR P&P: LV fixed or contactor switched automatic capacitor banks

Automatic capacitor banks with detuned filters (contactors switching), type P=7% (fres=189 Hz), 50 Hz. 32 models, supplied across Saudi Arabia by Volt Solutions.

  • Use voltage (V): 440
  • 32 models available

Information

The Circutor OPTIM FR P&P series (LV fixed or contactor switched automatic capacitor banks) has 32 models. Ordering codes: R54R64, R54R74, R54R81, R54R88, R54R92, R54R95 and 26 more. Model names include OPTIM FRS-P&P-31,25-440, OPTIM FRS-P&P-43,75-440, OPTIM FRS-P&P-62,5-440. Volt Solutions supplies it across Saudi Arabia.

The OPTIM FR P&P Series capacitor banks with detuned filters have been designed for power compensation purposes in networks with fluctuating load levels, a high content of harmonics and where there is a risk of resonance. Power variations are relatively slow (in seconds) so that the switching operations are carried out with contactors.

Applications

Its application is mainly focused on the compensation of installations with different loads, which require a regulated compensation, as a result of the power factor variations and where there is a high content of harmonics in the network.

  • Fixed detuned filters. For the compensation of transformers and motors (OPTIM FRF / FRM)
  • Automatic detuned filters, For the monitoring of variable loads (OPTIM FR P&P).

Specifications

Electrical characteristics
Voltage400 V (50 Hz) (other voltages on request)
Reinforcement voltage440 V
Surge10 % 8 h over 24 h 15 % up to 15 min over 24 hours 20 % up to 5 min over 24 hours 30 % up to 1 min over 24 hours
Manoeuvre voltageContactors: 230 V
Discharge resistance75 V / 3 min
Tolerance C-5% / 10 %
Losses (W)< 0,5 W/kvar
Current measurement circuit
Permanent overload1,3 In
Transformation ratioIn / 5A
Environmental characteristics
Working temperatureTª class D: Daily average: 45 ºC, annual average: 35 ºC, maximum: 55 ºC, minimum: -50 ºC
Relative humidity (without condensation)80%
Protection classIP 21
Mechanical characteristics
EnvelopeSheet metal RAL 7035 Grey / RAL 3005 Garnet
FasteningVertical / Self-supporting
Thermal managementNatural or forced according to options
Protection
ElementIndividual protection of each step with fuses with high rupture power (HRP). NH-00 Series.
Features / performance
OptionalManual capacitor bank header switch Automatic capacitor bank header switch Automatic switch + Earth leakage protection at the capacitor bank’s header Forced ventilation unit + thermostat Polycarbonate plate to protect against direct contacts
Standards
StandardsIEC 60831-1, UNE 60831-1, IEC 61921, IEC 60439, IEC 61439
Electrical safety, Maximum height (m)2000 m

Models and codes

CodeModel Cable section (mm2)Stepskvar (400 V)kvar (440 V)CompositionOptional circuit breaker (A) Quote
R54R64 OPTIM FRS-P&P-31,25-440 1032631,256,25 + 2 x 12,5– Get quote
R54R74 OPTIM FRS-P&P-43,75-440 2533643,756,25 + 12,5 + 25– Get quote
R54R81 OPTIM FRS-P&P-62,5-440 3535262,512,5 + 2 x 25– Get quote
R54R88 OPTIM FRS-P&P-90-440 70474902 x 15 + 2 x 30– Get quote
R54R92 OPTIM FRS-P&P-105-440 7048710515 + 3 x 30– Get quote
R54R95 OPTIM FRS-P&P-120-440 954991204 x 30– Get quote
R54S24 OPTIM FR4-P&P-150-440 95312515030 + 2 x 60400 Get quote
R54S25 OPTIM FR4-P&P-175-440 120314517525 + 50 + 100400 Get quote
R54S28 OPTIM FR4-P&P-200-440 150316520050 + 50 + 100400 Get quote
R54S29 OPTIM FR4-P&P-250-440 185320725050 + 2 x 100630 Get quote
R54S30 OPTIM FR4-P&P-300-440 240424830050 + 50 + 2 x 100630 Get quote
R54S32 OPTIM FR4-P&P-350-440 2×150428935050 + 3 x 100630 Get quote
R54S34 OPTIM FR4-P&P-400-440 2×15043314004 x 100800 Get quote
R54T25 OPTIM FR6-P&P-400-440 2×185533140050 + 50 + 3 x 100800 Get quote
R54T30 OPTIM FR6-P&P-450-440 2×185537245050 + 4 x 100800 Get quote
R54T35 OPTIM FR6-P&P-500-440 2×24054135005 x 1001000 Get quote
R54T40 OPTIM FR6-P&P-550-440 2×240645555050 + 5 x 1001000 Get quote
R54T45 OPTIM FR6-P&P-600-440 2×24064966006 x 1001000 Get quote
R54U36 OPTIM FR8-P&P-600-440 2×240749660050 + 50 + 5 x 1001250 Get quote
R54U38 OPTIM FR8-P&P-650-440 3×150753765050 + 6 x 1001250 Get quote
R54U40 OPTIM FR8-P&P-700-440 3×15075797007 x 1001250 Get quote
R54U42 OPTIM FR8-P&P-750-440 3×185862075050 + 7 x 1001600 Get quote
R54U44 OPTIM FR8-P&P-800-440 3×18586618008 x 1001600 Get quote
R54V25 OPTIM FR10-P&P-800-440 2×240/ 24086618008 x 1001000+400 Get quote
R54V30 OPTIM FR10-P&P-850-440 2×240/ 240970285050 + 8 x 1001000+630 Get quote
R54V35 OPTIM FR10-P&P-900-440 2×240/ 24097449009 x 1001000+630 Get quote
R54V40 OPTIM FR10-P&P-950-440 2×240/ 2×1851078595050 + 9 x 1001000+800 Get quote
R54V45 OPTIM FR10-P&P-1000-440 2×240/ 2×18510826100010 x 1001000+800 Get quote
R54W50 OPTIM FR12-P&P-1050-440 2×240/ 2×24011868105050 + 10 x 1001000+1000 Get quote
R54W55 OPTIM FR12-P&P-1100-440 2×240/ 2×24011909110011 x 1001000+1000 Get quote
R54W60 OPTIM FR12-P&P-1150-440 2×240/ 2×24012950115050 + 11 x 1002×1000 Get quote
R54W65 OPTIM FR12-P&P-1200-440 2×240/ 2×24012992120012 x 1002×1000 Get quote

Downloads

Support from our engineers