CVM-C11: Power analyzer, panel mounted 96 x96
Power analyzer, panel mounted 96 x96. 8 models, supplied across Saudi Arabia by Volt Solutions.
- Protocol: Modbus TCP/IP, BACnet, Modbus RTU
- Communications: Ethernet, RS-485
- 8 models available
Information
The Circutor CVM-C11 series (power analyzer, panel mounted 96 x96) has 8 models. Ordering codes: M58531, M58541, M58581, M58561, M58562, M58563 and 2 more. Model names include CVM-C11-ITF-IN-ETH-ICT2, CVM-C11-ITF-IN-485-ICT2, CVM-C11-MC-IN-485-ICT2. Volt Solutions supplies it across Saudi Arabia.
The CVM-C11 is a power analyzer for a panel (96 x 96 mm) with power logging. Ideal for analyzing electrical and consumption quality variables, such as THD% for voltage and current, as well as individual harmonics for each phase up to the 31st. The inclusion of neutral current measurement lets users detect any imbalance, as well as detect overloads in the neutral conductor. Compact and versatile with measurements in 4 quadrants (consumption and generation), suitable for medium- and low-voltage installations.
Display and interface characteristics:
- User-defined parameter display.
- Backlit screen
- On-screen graphic display of instantaneous active power
- On-screen graphic display of all quadrants (Q1, Q2, Q3, Q4).
- On-screen numerical indication of the value of cos φ or PF.
- On-screen indication of the status of outputs, inputs and/or active tariff.
- LED alarm indicator
- Costs, kg of CO2 emitted and operating time per tariff
Applications
- Discrimination of power consumption into three tariffs. Ideal for determining consumption during three different work shifts or from three different energy sources (grid, generator and photovoltaic generation), using the digital inputs.
- Generation of an impulse signal related to cost, kg of CO2 emitted or proportional to energy consumption or generation.
- Alarm control (2 relay outputs + 2 digital outputs) for any instantaneous parameter, whether measured or calculated. Adjustable based on maximum/minimum value, hysteresis (%), NO/NC, connection/disconnection delay and interlocks.
Specifications
| Nominal voltage | 100 … 270 V ~ ± 10% |
|---|---|
| Frequency | 50 … 60 Hz |
| Installation category | CAT III 300 V |
| Nominal voltage | 100 … 270 Vdc ± 10% |
|---|---|
| Installation category | CAT III 300 V |
| Nominal voltage | 230V Ph-N, 380V Ph-Ph |
|---|---|
| Frequency measuring range | 45 … 65 Hz |
| Input impedance | > 1.7 MΩ |
| Minimum measurement voltage (Vstart) | 10 V ~ |
| Maximum value | 300 VF-N /520 VF-F |
| Installation category | CAT III 300 V |
| Installation category | CAT III 300 V |
|---|
| Phase voltage measurement | 0.2% (5 …120% Un) |
|---|---|
| Power factor measurement | 0.5 % |
| Quantity | 2 |
|---|---|
| Type | NPN |
| Maximum voltage | 24 Vdc |
| Maximum current | 50 mA |
| Maximum frequency | 16 imp / s |
| Pulse width | 30 ms a 400 ms (Programmable) |
| Electrical life (at maximum load) | 60×10 3 cycles |
|---|---|
| Mechanical life | 10×10 6 cycles |
| Maximum switching capacity | 625 VA / 75 W (AC1) |
| Quantity | 2 |
|---|---|
| Type | NPN |
| Input/output insulation | 2000 V |
| Technology / Type | RS-485 |
|---|
| Display type | LCD Custom COG |
|---|---|
| Keyboard | 3 keys |
| Working temperature | -25 …+70 ºC |
|---|---|
| Storage temperature | -25 …+75 ºC |
| Relative humidity (without condensation) | 5 … 95% |
| Protection class | IP 54 (Front), IK 08 |
| Envelope | Self-extinguishing V0 plastic |
|---|---|
| Fastening | Panel |
| Size (mm) width x height x depth | 96 x 96 x 67.2 (mm) |
Models and codes
| Code | Model | Protocol | Communications | Transistor output | Relays | Digital inputs | Measuring Channels | Quote |
|---|---|---|---|---|---|---|---|---|
| M58531 | CVM-C11-ITF-IN-ETH-ICT2 | Modbus TCP/IP | BACnet | Ethernet | 2 | 2 | 2 | 4 | Get quote |
| M58541 | CVM-C11-ITF-IN-485-ICT2 | Modbus RTU | BACnet | RS-485 | 2 | 2 | 2 | 4 | Get quote |
| M58581 | CVM-C11-MC-IN-485-ICT2 | Modbus RTU | BACnet | RS-485 | 2 | 2 | 2 | 4 | Get quote |
| M58561 | CVM-C11-FLEX-IN-485-ICT2 | Modbus RTU | BACnet | RS-485 | 2 | 2 | 2 | 4 | Get quote |
| M58562 | CVM-C11-FLEX+3 MFC-FLEX-80 | – | – | – | – | – | – | Get quote |
| M58563 | CVM-C11-FLEX+3 MFC-FLEX-125 | – | – | – | – | – | – | Get quote |
| M58564 | CVM-C11-FLEX+4 MFC-FLEX-80 | – | – | – | – | – | – | Get quote |
| M58565 | CVM-C11-FLEX+4 MFC-FLEX-125 | – | – | – | – | – | – | Get quote |