CVM-D41 DC: DC power analyzer
Manufactured by Circutor

CVM-D41 DC: DC power analyzer

DC power analyzer. 2 models, supplied across Saudi Arabia by Volt Solutions.

  • Protocol: Modbus RTU
  • Módules: 6
  • IP: 54
  • Communications: RS-485
  • Relays: 2
  • Digital inputs: 2
  • Analog output: 1 (20 mA)
  • System: DC (Shunt)
  • 2 models available

Information

The Circutor CVM-D41 DC series (DC power analyzer) has 2 models. Ordering codes: M56638, M566380040000. Volt Solutions supplies it across Saudi Arabia.

The CVM-D41 DC is a digital power analyzer for installing on a DIN rail. Its screens are operated using buttons to display different electrical parameters in a DC network of up to 1500 VDC, such as voltage, current, power and energy (A·h).

This analyzer has the following key features:

  • DIN rail installation.
  • DC voltage measurement up to 1500VDC CATIIII
  • Shunt current measurement
  • 2 digital inputs + 2 relay outputs + 1 analogue output (0/4…20 mA) or (0 / 2 … 10 Vdc), depending on the model
  • LED status indicator
  • RS-485 communications (Modbus/RTU)
  • Configuration via Power Studio SCADA

Applications

Measurement and management of installations with a DC power supply:

  • Industrial Applications
  • Electric vehicle charging points
  • Self-supply systems
  • Solar photovoltaic Installations
  • HVAC
  • Industrial process control

Specifications

AC power supply
Installation categoryCAT III 300V
DC power supply
Installation categoryCAT III 300 V
Voltage measurement circuit
Nominal voltage± 150 / 300 / 600 / 1000 / 1500 Vdc
Maximum permanent measurement voltage1.2 Un continuous
Consumption< 1 VA
Installation categoryCAT III 1500 V
Current measurement circuit
Nominal current (In)Shunt: 50 / 60 /75 / 100 / 150 / 200 / 250 / 300 / 400 / 600 mV
Allowable overload1.2 In continuous (max.1500 Vdc)
Consumption< 1 VA
Installation categoryCAT III 1500 V
Measurement accuracy
Phase voltage measurementClass 0.5
Phase current measurementClass 0.5
Active power measurement (kW)Class 1
Active energy measurement (kWh)Class 1
Digital relay outputs
Quantity2
Maximum current2.5 A
Electrical life1 x 10 5 (250 V~ / 5A)
Maximum switching capacity625 VA
Digital inputs
Quantity2
TypePotential-free contact
Input/output insulation4000 V ~
Maximum short-circuit current3.3 mA dc
Maximum open circuit voltage17 V dc
Analogue outputs
Quantity1
Maximum internal voltage17 V dc
Linearity0.5 %
Current mode, nominal range0 … 20 mA, 4 … 20 mA, 4-12-20 mA
Current mode: maximum load resistance350 Ω
Serial communication
Technology / TypeRS-485
ProtocolModBus RTU
User interface
Display typeLCD 5 digits
Keyboard4 keys
Environmental characteristics
Working temperature-25 … +70 ºC
Storage temperature-25 … +70 ºC
Relative humidity (without condensation)≤ 93 %
Protection classFront: IP54, Rear: IP20
Mechanical characteristics
EnvelopePC + ABS
FasteningDIN rail
Weight (kg)0,7
Size (mm) width x height x depth108 x 117.43 x 74 (mm)
Standards
StandardsIEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61010-1, IEC 61326-1, IEC 61010-2-030
Electrical safety, Contamination level/classPollution resistance 2
Electrical safety, Maximum height (m)2000

Models and codes

CodeModel Measurement Range (V)Measurement Range (A) Quote
M56638 CVM-D41 DC mA ± 150…1500 Vdc50 … 600 mV Get quote
M566380040000 CVM-D41 DC mA ± 150 / 300 /600 / 1000 / 1500 Vdc50 / 60 / 75 / 100 / 150 / 200 / 250 / 300 / 400 / 600 mV Get quote