CVM-D50: Din rail three-phase power analyser with memory
Manufactured by Circutor

CVM-D50: Din rail three-phase power analyser with memory

Din rail three-phase power analyser with memory. 3 models, supplied across Saudi Arabia by Volt Solutions.

  • Protocol: Modbus TCP/IP
  • Memory: Yes
  • Communications: Ethernet, Wi-Fi
  • Harmonics: 31
  • Power supply: 90…264 Vac/Vdc
  • Mounting: DIN rail
  • 3 models available

Information

The Circutor CVM-D50 series (din rail three-phase power analyser with memory) has 3 models. Ordering codes: M56570, M56580, M56590. Model names include CVM-D50-ITF, CVM-D50-MC, CVM-D50-FLEX. Volt Solutions supplies it across Saudi Arabia.

Three-phase power analyzer (balanced and unbalanced) for assembly on DIN rail, very small, with 4-quadrant measurements and integrated memory for data logging. Main features include: • Current measurement (depending on model) …/5 or…/1 A or…/250 mA or Rogowski-type sensors. • Wi-Fi and Ethernet communications (Modbus TCP/IP). • Integrated memory. • With web Server to view, configure and download data. • Compatible with the MyConfig app. • Sealable with terminal cover. • Display of THD% and up to the 31st harmonic (V, A). • DIN rail format just 3 modules wide. • High-contrast backlit display. • 72 x 72 mm panel mount with front adapter. • Includes an operating-hours and working-hours counter for CAE.

Applications

• Control application in distribution panels and low- and medium-voltage connections where an analyzer has to be installed on the DIN rail due to space constraints.
• Alarm control: Maximum value, minimum, delay and programmable interlocking.
• Logging of active or capacitive and inductive reactive energy.
• Capture and storage of instantaneous, maximum and minimum data of the electrical parameters measured.

Specifications

AC power supply
Nominal voltage100 … 240 V~ ± 10 %
Frequency50…60 Hz
Installation categoryCAT III 300 V
DC power supply
Nominal voltage100 … 240 Vd.c. ± 10 %
Consumption1,8 … 2 W
Voltage measurement circuit
Nominal voltage230V Ph-N, 400V Ph-Ph
Frequency measuring range45…65 Hz
Input impedance400 kΩ
Minimum measurement voltage (Vstart)11,5 V Ph-N
Installation categoryCAT III 300 V
Current measurement circuit
Maximum input current consumption0,9 VA
Installation categoryCAT III 300 V
Measurement accuracy
Phase voltage measurement0.5% ± 1 digit (5 … 120 % Un)
Frequency measurement0,50%
Wireless communication
Technology / TypeWi-Fi, IEEE 802.11 b/g, IEEE 802.11 n (Up 150 Mbps)
BandWi-Fi (2.4 … 2.5 GHz.)
Communication Network
Technology / InterfaceEthernet
ProtocolModbus TCP – Web server
User interface
Display typeLCD Custom COG
Keyboard3 keys
Environmental characteristics
Working temperature-10 … +50 ºC
Storage temperature-30 … +80 ºC
Relative humidity (without condensation)5…95%
Protection classIP 30 / Front: IP 40, IK08
Mechanical characteristics
EnvelopeSelf-extinguishing V0 plastic
FasteningDIN rail
Size (mm) width x height x depth52.5 x 118 x 74 (mm)
Standards
StandardsIEC/EN 61010-1; IEC/EN 61010-2-030; UNE-EN 55016-2-1; UNE-EN 61000-4-2; UNE-EN 61000-4-20; UNE-EN 61000-4-4; UNE-EN 61000-4-5; UNE-EN 61000-4-6; UNE-EN 61000-4-8; UNE-EN IEC 61000-4-11; UNE-EN 61000-4-3; ETSI-EN 301 489-1 Ver. 2.1.1; ETSI-EN 301 489-17 Ver. 3.1.1; UNE-EN 60068-2-1; UNE-EN 60068-2-2:2008; UNE-EN 60068-2-78; IEC 61557-12; EN 18031-1
Electrical safety, Contamination level/class2
Electrical safety, Maximum height (m)2000

Models and codes

CodeModel Input current Quote
M56570 CVM-D50-ITF …/5 A | …/1 A Get quote
M56580 CVM-D50-MC …/250 mA Get quote
M56590 CVM-D50-FLEX Rogowski Get quote